BM3 Pro
Multi-Parameter Patient Monitor
Versatile, portable, and lightweight, the BM3 Pro patient monitor is specially designed to be reliable and user-friendly. The compact design, coupled with a unique handle, makes it easy to move from room to room. Its 8″ high resolution LCD touch screen displays all the vital signs in different colors for easy recognition.
Thank you for your interest in Bionet’s products.
Please fill out the Sales Inquiry form to receive pricing and purchasing information. Thank you, once again, for your interest in Bionet America.* Bionet medical products are approved for the United States.For sales inquiries outside of the USA, please contact Bionet Korea at [email protected]. Close |
or |
BUY NOW |

Versatile, portable, and lightweight, the BM3 Pro patient monitor is specially designed to be reliable and user-friendly. The compact design, coupled with a unique handle, makes it easy to move from room to room. Its 8″ high resolution LCD touch screen displays all the vital signs in different colors for easy recognition.
Thank you for your interest in Bionet’s products.
Please fill out the Sales Inquiry form to receive pricing and purchasing information. Thank you, once again, for your interest in Bionet America.* Bionet medical products are approved for the United States.For sales inquiries outside of the USA, please contact Bionet Korea at [email protected]. Close |
or |
BUY NOW |

Product Highlights
ECG, SpO2, NIBP, Respiration and Temperature
8.0″ color TFT touch screen with 4 wave forms
Mainstream/Sidestream EtCO2 (optional)
Multiple display modes
External HDMI output for large screen
Li-ion rechargeable battery allows cordless use up to 2 hours
Quick Link
● Materials Download
● Specifications
wdt_ID | Item | Feature | Specification |
---|---|---|---|
73 | General | Display, Resolution | 8' wide color touch TFT LCD, 800 x 600 pixels |
74 | Dimension, Weight | 238 (W) x 250 (H) x 163 (D) mm, approx. 3.1 kg | |
75 | Trace | 4 waveforms: 2*ECG, SpO2, respiration Swap speed: 6.25, 12.5, 25, 50 mm/sec. |
|
77 | Indicators | Categorized alarms (3 priority levels) Visual alarm QRS beep & SpO2 pulse beep Percent (%) SpO2 pitch tone Battery Status, external power LED Rotary Knob |
|
78 | Interfaces | Power supply: AC 100 - 240 V (50/60 Hz) DC input connector: 18 VDC, 2.8 A LAN digital output for transferring data Nurse call system connection: - 0.3 A at 125 VAC - 1 A at 24 VDC External HDMI output for large screen USB barcode reader USB memory data storage/Software upgrade |
|
79 | Battery | Rechargeable Li-ion battery Approx 2 hours of continuous operation |
|
80 | Thermal Printer (Option) | Speed: 25, 50 mm/sec. Paper Width: 58 mm |
|
82 | Data Storage | 168 hours of trend data, 20 cases of 10 sec. alarm waveform | |
83 | Language | English, French, Spanish, Italian, German, Chinese, Russian, Czech, Polish, Turkish, Romanian, Portuguese, Bulgarian, Hungarian, Korean, Japanese, Greek | |
84 | Standard Accessories | 3-lead ECG cable with extension - 1 ea Electrodes - 10 ea NIBP extension hose (3 m) - 1 ea NIBP adult cuff (23-33/27.5-36.5 cm) - 1 ea SpO2 extension cable (2 m) - 1 ea Reusable adult SpO2 probe - 1 ea DC adapter (18VDC, 2.8A) with power code - 1 ea Paper roll - 2 ea |
|
85 | Optional Accessories | 5-lead ECG cable Temperature probe (skin) NIBP cuff (reusable/disposable) |
|
86 | Optional Module | Mainstream EtCO2 airway adapter kit (sensor) Sidestream EtCO2 airway adapter kit (sensor) |
|
87 | ECG | Lead Type | 3-lead, 5-lead (Option) |
88 | Lead Selection | 3-lead: I, II, III 5-lead (Option): I, II, III, aVR, aVL, aVF, V |
|
89 | ECG Waveforms | 3-lead: 1 channel 5-lead (Option): 1 channel |
|
90 | Heart Rate Range | Adult: 30 to 300 bpm Neonate/Pediatric: 30 to 350 bpm |
|
91 | Heart Rate Accuracy | +/-1 bpm or +/- 1%, whichever is greater | |
92 | Sweep Speed | 6.25, 12.5, 25, 50 mm/sec. | |
93 | Filter | - Diagnoses: 0.05 tp 150 Hz - Monitoring: 0.5 to 40 Hz - Moderate: 0.5 to 25 Hz - Maximum: 5 to 25 Hz |
|
94 | Pacemaker Detection Mode | Indicator on waveform display (user selectable) | |
95 | Protection | Against electrosurgical interference and defibrillation | |
96 | Respiration | Method | Thoracic impedance |
97 | Channel Selection | RA-LA or RA-LL | |
98 | Measurement Range | 5 to 120 breaths per minute | |
99 | Accuracy | +/- 1 breath per minute | |
100 | SpO2 | Saturation Range | 0 to 100 % |
101 | Saturation Accuracy | 70 to 100 % +/- 2 digits, 0 to 69 % unspecified | |
102 | Pulse Rate Range | 30 to 254 bpm | |
103 | Pulse Rate Accuracy | +/- 2 bpm | |
104 | NIBP (Suntech) | Method | Oscillometery |
105 | Operation Mode | Manual / Automatic / Continuous | |
106 | Pressure Range | 0 to 300 mmHg (accuracy +/- 3 mmHg) | |
107 | Safety Pressure | Adult pressure: 20 to 260 mmHg Pulse rate: 30 to 220 BPM Pediatric pressure: 20 to 160 mmHg Pulse rate: 30 to 220 BPM Neonate pressure: 20 to 130 mmHg Pulse rate: 30 to 220 BPM |
|
108 | Accuracy | Meets accuracy requirements of ANSI / AAMI SP10: 1992 AND 2002 | |
109 | Temperature (only probe option) | Measurement Range | 0 to 50°C (32 to 12250°F) |
110 | Accuracy | 25°C to 50°C: +/- 0.1°C 0°C to 24°C: +/- 0.2°C |
|
111 | Compatibility | YSI series 400 temperature probes | |
112 | Sidestream EtCO2 - Respironics (option) | Measurement Range | 0 to 150 mmHg, 0 to 19% |
113 | Accuracy | 0 to 40 mmHg +/- 2 mmHg, 41 to 70 mmHg +/- 5 % of reading, 71 to 100 mmHg +/- 8 % of reading, 101 to 150 mmHg +/- 10 % of reading | |
114 | Respiration Rate | 2 to 150 breaths per minute | |
115 | Respiration Accuracy | +/- 1 breath per minute | |
116 | Mainstream EtCO2 - Respironics (option) | Measurement Range | 0 to 150 mmHg, 0 to 19% |
117 | Accuracy | 0 to 40 mmHg +/- 2 mmHg, 41 to 70 mmHg +/- 5 % of reading, 71 to 100 mmHg +/- 8 % of reading, 101 to 150 mmHg +/- 10 % of reading | |
118 | Respiration Rate | 0 to 150 breaths per minute | |
119 | Respiration Accuracy | +/- 1 breath per minute |
* Specifications can be changed without prior notification.
Close
● Accessories
Item Code | Item Description | |||
---|---|---|---|---|
wdt_ID | Item Image | Item Code | Item Description | Buy Now |
1 | B-CBL-N | 3 lead ECG extension cable | Buy Now | |
2 | B-CBL5-N | 5 lead ECG extension cable | Buy Now | |
3 | B-WIRE-SA | 3 lead ECG cable (Snap type) | Buy Now | |
4 | B-WIRE5-SA | 5 lead ECG cable (Snap Type) | Buy Now | |
5 | B-SPCBL-N | SpO2 extension cable | Buy Now | |
6 | B-SPO2-FA | SpO2 adult finger sensor | Buy Now | |
8 | B-NBPCBL | NIBP extension tube | Buy Now | |
9 | B-ACUFF-L | NIBP adult cuff large (arm circumference: 35.5~46 cm) | Buy Now | |
10 | B-ACUFF | NIBP adult cuff (arm circumference: 27.5~36.5 cm) | Buy Now | |
11 | B-CCUFF | NIBP child cuff (arm circumference: 20.5~28.5 cm) | Buy Now | |
13 | B-PCUFF | NIBP pediatric cuff (arm circumference: 13.8~21.5 cm) | Buy Now | |
18 | B-ICUFF | NIBP infant cuff (arm circumference: 9~14.8 cm) | Buy Now | |
19 | TRANS | Power transformer (DC adaptor) | Buy Now | |
20 | PC-A (H) | Hospital grade power cable | Buy Now | |
21 | BM-BAT-3&5 | Battery Console Li-ion 10.8V/2150mAh, 3 line | Buy Now | |
22 | B-ME-S | ECG monitoring electrode snap type (30 electrodes/pouch) | Buy Now | |
23 | B-SPO2-FAND | SpO2 adult and neonate finger sensor disposable | Buy Now | |
24 | B-NCUFF-SET | NIBP neonate cuffs (1 of each, #1-#5) | Buy Now | |
30 | B-NCUFF1 | NIBP neonate cuff #1 | Buy Now | |
31 | B-NCUFF2 | NIBP neonate cuff #2 | Buy Now | |
32 | B-NCUFF3 | NIBP neonate cuff #3 | Buy Now | |
33 | B-NCUFF4 | NIBP neonate cuff #4 | Buy Now | |
34 | B-NCUFF5 | NIBP neonate cuff #5 | Buy Now | |
35 | BM-PP | BM paper (10 rolls/box) | Buy Now | |
36 | B-RMCO2 | CAPNOSTAT 5 mainstream CO2 sensor (includes one of each single use airway adapter, items 6063-00 and 6312-00) | Buy Now | |
45 | B-RSCO2-M | LoFlo sidestream CO2 sensor (includes mounting bracket and two sampling lines with male Luer adapter, item 3475-00) | Buy Now | |
46 | 3473ADU-00 | Airway adapter kit with dehumidification, up to 120 hours – adult/pediatric: ET tube > 4 mm | Buy Now | |
47 | 3473INF-00 | Airway adapter kit with dehumidification, up to 120 hours – infant/neonate: ET tube ≤ 4 mm | Buy Now | |
48 | 3475-00 | Sampling line with male Luer adapter | Buy Now | |
49 | 3468ADU-00 | Adult nasal CO2 sampling cannula, single patient use. | Buy Now | |
50 | 3469ADU-00 | Adult nasal CO2 with O2 delivery sampling cannula, single patient use. | Buy Now | |
51 | B-RSCO2-MB | Mounting bracket for LoFlo sidestream unit | Buy Now | |
52 | 6063-00 | Single patient use adult airway adapter: ET tube > 4 mm | Buy Now | |
53 | 6312-00 | Single patient use neonatal airway adapter: ET tube ≤ 4 mm | Buy Now | |
54 | 7007-01 | Reusable adult/pediatric airway adapter: ET tube > 4 mm | Buy Now | |
61 | 7053-01 | Reusable infant/neonatal airway adapter: ET tube ≤ 4 mm | Buy Now | |
62 | BM-CART-H | BM series rolling cart with cable hanger (90-day warranty) | Buy Now | |
63 | BM-WM | Wall Mount for BM Series Monitor | Buy Now | |
64 | TEM-PRV-RA | Temperature Probe Adult (Esophageal/Rectal Type) | Buy Now | |
65 | TEM-PRV-RP | Temperature Probe Pediatric (Esophageal/Rectal Type) | Buy Now | |
66 | TEM-PRV-SA | Temperature Probe Adult (Skin Type) | Buy Now | |
67 | TEM-PRV-SP | Temperature Probe Pediatric (Skin Type) | Buy Now |
Close
Product Highlights
ECG, SpO2, NIBP, Respiration and Temperature
8.0″ color TFT touch screen with 4 wave forms
Mainstream/Sidestream EtCO2 (optional)
Multiple display modes
External HDMI output for large screen
Li-ion rechargeable battery allows cordless use up to 2 hours
Quick Link
● Materials Download
● Specifications
wdt_ID | Item | Feature | Specification |
---|---|---|---|
73 | General | Display, Resolution | 8' wide color touch TFT LCD, 800 x 600 pixels |
74 | Dimension, Weight | 238 (W) x 250 (H) x 163 (D) mm, approx. 3.1 kg | |
75 | Trace | 4 waveforms: 2*ECG, SpO2, respiration Swap speed: 6.25, 12.5, 25, 50 mm/sec. |
|
77 | Indicators | Categorized alarms (3 priority levels) Visual alarm QRS beep & SpO2 pulse beep Percent (%) SpO2 pitch tone Battery Status, external power LED Rotary Knob |
|
78 | Interfaces | Power supply: AC 100 - 240 V (50/60 Hz) DC input connector: 18 VDC, 2.8 A LAN digital output for transferring data Nurse call system connection: - 0.3 A at 125 VAC - 1 A at 24 VDC External HDMI output for large screen USB barcode reader USB memory data storage/Software upgrade |
|
79 | Battery | Rechargeable Li-ion battery Approx 2 hours of continuous operation |
|
80 | Thermal Printer (Option) | Speed: 25, 50 mm/sec. Paper Width: 58 mm |
|
82 | Data Storage | 168 hours of trend data, 20 cases of 10 sec. alarm waveform | |
83 | Language | English, French, Spanish, Italian, German, Chinese, Russian, Czech, Polish, Turkish, Romanian, Portuguese, Bulgarian, Hungarian, Korean, Japanese, Greek | |
84 | Standard Accessories | 3-lead ECG cable with extension - 1 ea Electrodes - 10 ea NIBP extension hose (3 m) - 1 ea NIBP adult cuff (23-33/27.5-36.5 cm) - 1 ea SpO2 extension cable (2 m) - 1 ea Reusable adult SpO2 probe - 1 ea DC adapter (18VDC, 2.8A) with power code - 1 ea Paper roll - 2 ea |
|
85 | Optional Accessories | 5-lead ECG cable Temperature probe (skin) NIBP cuff (reusable/disposable) |
|
86 | Optional Module | Mainstream EtCO2 airway adapter kit (sensor) Sidestream EtCO2 airway adapter kit (sensor) |
|
87 | ECG | Lead Type | 3-lead, 5-lead (Option) |
88 | Lead Selection | 3-lead: I, II, III 5-lead (Option): I, II, III, aVR, aVL, aVF, V |
|
89 | ECG Waveforms | 3-lead: 1 channel 5-lead (Option): 1 channel |
|
90 | Heart Rate Range | Adult: 30 to 300 bpm Neonate/Pediatric: 30 to 350 bpm |
|
91 | Heart Rate Accuracy | +/-1 bpm or +/- 1%, whichever is greater | |
92 | Sweep Speed | 6.25, 12.5, 25, 50 mm/sec. | |
93 | Filter | - Diagnoses: 0.05 tp 150 Hz - Monitoring: 0.5 to 40 Hz - Moderate: 0.5 to 25 Hz - Maximum: 5 to 25 Hz |
|
94 | Pacemaker Detection Mode | Indicator on waveform display (user selectable) | |
95 | Protection | Against electrosurgical interference and defibrillation | |
96 | Respiration | Method | Thoracic impedance |
97 | Channel Selection | RA-LA or RA-LL | |
98 | Measurement Range | 5 to 120 breaths per minute | |
99 | Accuracy | +/- 1 breath per minute | |
100 | SpO2 | Saturation Range | 0 to 100 % |
101 | Saturation Accuracy | 70 to 100 % +/- 2 digits, 0 to 69 % unspecified | |
102 | Pulse Rate Range | 30 to 254 bpm | |
103 | Pulse Rate Accuracy | +/- 2 bpm | |
104 | NIBP (Suntech) | Method | Oscillometery |
105 | Operation Mode | Manual / Automatic / Continuous | |
106 | Pressure Range | 0 to 300 mmHg (accuracy +/- 3 mmHg) | |
107 | Safety Pressure | Adult pressure: 20 to 260 mmHg Pulse rate: 30 to 220 BPM Pediatric pressure: 20 to 160 mmHg Pulse rate: 30 to 220 BPM Neonate pressure: 20 to 130 mmHg Pulse rate: 30 to 220 BPM |
|
108 | Accuracy | Meets accuracy requirements of ANSI / AAMI SP10: 1992 AND 2002 | |
109 | Temperature (only probe option) | Measurement Range | 0 to 50°C (32 to 12250°F) |
110 | Accuracy | 25°C to 50°C: +/- 0.1°C 0°C to 24°C: +/- 0.2°C |
|
111 | Compatibility | YSI series 400 temperature probes | |
112 | Sidestream EtCO2 - Respironics (option) | Measurement Range | 0 to 150 mmHg, 0 to 19% |
113 | Accuracy | 0 to 40 mmHg +/- 2 mmHg, 41 to 70 mmHg +/- 5 % of reading, 71 to 100 mmHg +/- 8 % of reading, 101 to 150 mmHg +/- 10 % of reading | |
114 | Respiration Rate | 2 to 150 breaths per minute | |
115 | Respiration Accuracy | +/- 1 breath per minute | |
116 | Mainstream EtCO2 - Respironics (option) | Measurement Range | 0 to 150 mmHg, 0 to 19% |
117 | Accuracy | 0 to 40 mmHg +/- 2 mmHg, 41 to 70 mmHg +/- 5 % of reading, 71 to 100 mmHg +/- 8 % of reading, 101 to 150 mmHg +/- 10 % of reading | |
118 | Respiration Rate | 0 to 150 breaths per minute | |
119 | Respiration Accuracy | +/- 1 breath per minute |
* Specifications can be changed without prior notification.
Close
● Accessories
Item Code | Item Description | |||
---|---|---|---|---|
wdt_ID | Item Image | Item Code | Item Description | Buy Now |
1 | B-CBL-N | 3 lead ECG extension cable | Buy Now | |
2 | B-CBL5-N | 5 lead ECG extension cable | Buy Now | |
3 | B-WIRE-SA | 3 lead ECG cable (Snap type) | Buy Now | |
4 | B-WIRE5-SA | 5 lead ECG cable (Snap Type) | Buy Now | |
5 | B-SPCBL-N | SpO2 extension cable | Buy Now | |
6 | B-SPO2-FA | SpO2 adult finger sensor | Buy Now | |
8 | B-NBPCBL | NIBP extension tube | Buy Now | |
9 | B-ACUFF-L | NIBP adult cuff large (arm circumference: 35.5~46 cm) | Buy Now | |
10 | B-ACUFF | NIBP adult cuff (arm circumference: 27.5~36.5 cm) | Buy Now | |
11 | B-CCUFF | NIBP child cuff (arm circumference: 20.5~28.5 cm) | Buy Now | |
13 | B-PCUFF | NIBP pediatric cuff (arm circumference: 13.8~21.5 cm) | Buy Now | |
18 | B-ICUFF | NIBP infant cuff (arm circumference: 9~14.8 cm) | Buy Now | |
19 | TRANS | Power transformer (DC adaptor) | Buy Now | |
20 | PC-A (H) | Hospital grade power cable | Buy Now | |
21 | BM-BAT-3&5 | Battery Console Li-ion 10.8V/2150mAh, 3 line | Buy Now | |
22 | B-ME-S | ECG monitoring electrode snap type (30 electrodes/pouch) | Buy Now | |
23 | B-SPO2-FAND | SpO2 adult and neonate finger sensor disposable | Buy Now | |
24 | B-NCUFF-SET | NIBP neonate cuffs (1 of each, #1-#5) | Buy Now | |
30 | B-NCUFF1 | NIBP neonate cuff #1 | Buy Now | |
31 | B-NCUFF2 | NIBP neonate cuff #2 | Buy Now | |
32 | B-NCUFF3 | NIBP neonate cuff #3 | Buy Now | |
33 | B-NCUFF4 | NIBP neonate cuff #4 | Buy Now | |
34 | B-NCUFF5 | NIBP neonate cuff #5 | Buy Now | |
35 | BM-PP | BM paper (10 rolls/box) | Buy Now | |
36 | B-RMCO2 | CAPNOSTAT 5 mainstream CO2 sensor (includes one of each single use airway adapter, items 6063-00 and 6312-00) | Buy Now | |
45 | B-RSCO2-M | LoFlo sidestream CO2 sensor (includes mounting bracket and two sampling lines with male Luer adapter, item 3475-00) | Buy Now | |
46 | 3473ADU-00 | Airway adapter kit with dehumidification, up to 120 hours – adult/pediatric: ET tube > 4 mm | Buy Now | |
47 | 3473INF-00 | Airway adapter kit with dehumidification, up to 120 hours – infant/neonate: ET tube ≤ 4 mm | Buy Now | |
48 | 3475-00 | Sampling line with male Luer adapter | Buy Now | |
49 | 3468ADU-00 | Adult nasal CO2 sampling cannula, single patient use. | Buy Now | |
50 | 3469ADU-00 | Adult nasal CO2 with O2 delivery sampling cannula, single patient use. | Buy Now | |
51 | B-RSCO2-MB | Mounting bracket for LoFlo sidestream unit | Buy Now | |
52 | 6063-00 | Single patient use adult airway adapter: ET tube > 4 mm | Buy Now | |
53 | 6312-00 | Single patient use neonatal airway adapter: ET tube ≤ 4 mm | Buy Now | |
54 | 7007-01 | Reusable adult/pediatric airway adapter: ET tube > 4 mm | Buy Now | |
61 | 7053-01 | Reusable infant/neonatal airway adapter: ET tube ≤ 4 mm | Buy Now | |
62 | BM-CART-H | BM series rolling cart with cable hanger (90-day warranty) | Buy Now | |
63 | BM-WM | Wall Mount for BM Series Monitor | Buy Now | |
64 | TEM-PRV-RA | Temperature Probe Adult (Esophageal/Rectal Type) | Buy Now | |
65 | TEM-PRV-RP | Temperature Probe Pediatric (Esophageal/Rectal Type) | Buy Now | |
66 | TEM-PRV-SA | Temperature Probe Adult (Skin Type) | Buy Now | |
67 | TEM-PRV-SP | Temperature Probe Pediatric (Skin Type) | Buy Now |
Close
Versatile, portable, and lightweight, the BM3 Pro patient monitor is specially designed to be reliable and user-friendly. The compact design, coupled with a unique handle, makes it easy to move from room to room. Its 8″ high resolution LCD touch screen displays all the vital signs in different colors for easy recognition. A built-in printer offers hard-copy documentation of all measured values, as well as up to 4 waveforms of information. Alarms and settings are easily adjustable and are retained after turning off the power. Plug-and-play side or mainstream EtCO2 sensor can be added at any time.
Intended Use: To monitor vital signs in patients, including: ECG, SpO2, NIBP, respiration, temperature and EtCO2. (Option: Temperature, EtCO2)
Superior Advantages
• ECG, SpO2, NIBP, respiration, temperature*, EtCO2*
• 8.0″ Color TFT Touch Screen with 4 Wave Forms
• Individual Sweep Speed Setting for Each Parameter
• SpO2 Measurement – Every Low Perfusion Detection / Pulse Beep
• Multiple Display Modes
• Screen Freeze On/Off
• 168 Full Hours of Trend Data Are Stored
• USB Memory Storage
• External HDMI Output for Large Screen
Enhanced & Extendible Multi-Parameter
• Sidestream/Mainstream EtCO2
High-Performance ECG Detection and Analysis
• Enhanced input impedance for dry skin or electrode patch
• Pacemaker detection function
Enhanced Data Management
• Graphical and tabular trends
• 20 cases – 10 sec. alarm waveform stored, reviewed and printed
• USB memory storage
Transportable
• Li-ion rechargeable battery allows cordless use up to 2 hours
• Less than 7 lbs, including battery
3-YEAR WARRANTY
Includes:
BM3 Pro Main Unit, 3 Lead ECG Cable (snap type) with Extension Cable, Electrodes, SpO2 Adult Finger Sensor and Extension Cable, NIBP Adult Cuff (arm circumference 25-35 cm) and Extension Tube, Chart Paper (x2), Power Adaptor & Hospital Grade Power Cord, Operation Manual, and 3-Year Warranty Card.
Options:
Temperature Probe (Skin), EtCO2 Sensor (Sidestream or Mainstream), and 5 Lead ECG Cable and Extension Cable



- Overview
-
Versatile, portable, and lightweight, the BM3 Pro patient monitor is specially designed to be reliable and user-friendly. The compact design, coupled with a unique handle, makes it easy to move from room to room. Its 8″ high resolution LCD touch screen displays all the vital signs in different colors for easy recognition. A built-in printer offers hard-copy documentation of all measured values, as well as up to 4 waveforms of information. Alarms and settings are easily adjustable and are retained after turning off the power. Plug-and-play side or mainstream EtCO2 sensor can be added at any time.
Intended Use: To monitor vital signs in patients, including: ECG, SpO2, NIBP, respiration, temperature and EtCO2. (Option: Temperature, EtCO2)
Superior Advantages
• ECG, SpO2, NIBP, respiration, temperature*, EtCO2*
• 8.0″ Color TFT Touch Screen with 4 Wave Forms
• Individual Sweep Speed Setting for Each Parameter
• SpO2 Measurement – Every Low Perfusion Detection / Pulse Beep
• Multiple Display Modes
• Screen Freeze On/Off
• 168 Full Hours of Trend Data Are Stored
• USB Memory Storage
• External HDMI Output for Large ScreenEnhanced & Extendible Multi-Parameter
• Sidestream/Mainstream EtCO2High-Performance ECG Detection and Analysis
• Enhanced input impedance for dry skin or electrode patch
• Pacemaker detection functionEnhanced Data Management
• Graphical and tabular trends
• 20 cases – 10 sec. alarm waveform stored, reviewed and printed
• USB memory storageTransportable
• Li-ion rechargeable battery allows cordless use up to 2 hours
• Less than 7 lbs, including battery3-YEAR WARRANTY
Includes:
BM3 Pro Main Unit, 3 Lead ECG Cable (snap type) with Extension Cable, Electrodes, SpO2 Adult Finger Sensor and Extension Cable, NIBP Adult Cuff (arm circumference 25-35 cm) and Extension Tube, Chart Paper (x2), Power Adaptor & Hospital Grade Power Cord, Operation Manual, and 3-Year Warranty Card.Options:
Temperature Probe (Skin), EtCO2 Sensor (Sidestream or Mainstream), and 5 Lead ECG Cable and Extension Cable - Specifications
-
- Accessories
-
- Downloads
-
Search
Quick Link
Contact Us
- Toll Free
1-877-9-BIONET (1-877-924-6638) - Tel
714-734-1760 - Fax
714-734-1761 - Sales
[email protected] - Customer service
[email protected]