In today’s veterinary healthcare environment, Capnography is becoming one of the most essential elements of monitoring.

Various plug & play capnography monitoring solutions from Bionet ensure the user to have confidence in the operation with accurate and reliable readings.

Various solutions

Various sensors, modules and all-in-one of display & module for anesthetic gas monitoring and EtCO2 monitoring

Plug and Play

All our capnography options are plug and play which makes the operation of clinic much easier

Safe & Reliable

Accurate and reliable readings ensure the user to have confidence in the operation

Warranty

All out capnography comes with 2-year warranty that exceeds the industry standard
Bionet Brio promo

Various solutions

Various sensors, modules and all-in-one of display & module for anesthetic gas monitoring and EtCO2 monitoring

Plug and Play

All our capnography options are plug and play which makes the operation of clinic much easier

Safe & Reliable

Accurate and reliable readings ensure the user to have confidence in the operation

Warranty

All out capnography comes with 2-year warranty that exceeds the industry standard

In today’s veterinary healthcare environment, Capnography is becoming one of the most essential elements of monitoring.

Various plug & play capnography monitoring solutions from Bionet ensure the user to have confidence in the operation with accurate and reliable readings.

Brio Monitor Promotion long banner
Bionet Dual Gas Module

DUAL GAS SENSOR

EtCO2 Sensor - B-RMCO2

EtCO2 Sensor - Mainstream

EtCO2 Sensor - B-RSCO2

EtCO2 Sensor - Sidestream

Image of Bionet EtCO2 Sensor MainStream

Bionet EtCO2 Sensor - Mainstream

Image of Bionet EtCO2 Sensor SideStream

Bionet EtCO2 Sensor - Sidestream

Bionet GA3VET - EtCO2/Anesthetic Gas Analyzer

GA3VET

DUAL GAS SENSOR

EtCO2 and Anesthetic Gas Monitoring Module

The Dual Gas module is a sidestream multi-gas analyzer measuring end-tidal carbon dioxide (EtCO2) and one of five anesthetic agents (isoflurane, sevoflurane, enflurane, halothane and desflurane) with manual selection of the specific agent type.

5 Major Gases

Isoflurane, sevoflurane, enflurane, halothane and desflurane

Sidestream

Gives a Sidestream EtCO2 reading

Add On

Works with BM Vet Series and GA3Vet monitors

No Calibration

Unit is self calibrating

Plug and Play

Ready for use

Warranty

2 year warranty

EtCO2 and Anesthetic Gas Monitoring Module

The Dual Gas module is a sidestream multi-gas analyzer measuring end-tidal carbon dioxide (EtCO2) and one of five anesthetic agents (isoflurane, sevoflurane, enflurane, halothane and desflurane) with manual selection of the specific agent type.

5 Major Gases

Isoflurane, sevoflurane, enflurane, halothane and desflurane

Sidestream

Gives a Sidestream EtCO2 reading

Add On

Works with BM Vet Series and GA3Vet monitors

No Calibration

Unit is self calibrating

Plug and Play

Ready for use

Warranty

2 year warranty
Learn MoreRequest Purchase Information
Bionet Dual Gas Module
Bionet Dual Gas Module
BM7Vet Elite - Bionet Multi-Parameter Touch Screen Veterinary Monitor

EtCO2 Sensor - Mainstream

EtCO2 Monitoring Module

EtCO2 monitoring is one of the easiest ways to alert for failing health conditions, such as hyper or hypothermia but requires highly accurate and durable sensor. Our mainstream sensor is manufactured by Philips Respironics, using sophisticated infrared absorption spectroscopy to measure EtCO2. Measurements are taken at the patient’s airway, so response is faster and there is less chance of erroneous, artifact date. And since there are not moving parts, our mainstream sensor is durable and provides reliable readings you can count on. Our mainstream comes with 2 year warranty and the package includes 1 each of the 2 size airway adapters (a larger adapter for tubes greater than 4mm and a smaller adapter for tubes less than or equal to 4mm).

Fast

Measurements are taken at the patient’s airway, so response time is fast – less than 60ms

Easy

Simply snap the sensor onto the airway adapter. There are no clips or latches to break

Accurate

Clear, precious CO2 measurement. No regular calibration is required

Reliable

Rugged design and construction minimized the downtime. No moving parts to replace

Lightweight

At just 25grams. Ideal for every patient

Warranty

2 year warranty
EtCO2 Sensor - B-RMCO2

EtCO2 Monitoring Module

EtCO2 monitoring is one of the easiest ways to alert for failing health conditions, such as hyper or hypothermia but requires highly accurate and durable sensor. Our mainstream sensor is manufactured by Philips Respironics, using sophisticated infrared absorption spectroscopy to measure EtCO2. Measurements are taken at the patient’s airway, so response is faster and there is less chance of erroneous, artifact date. And since there are not moving parts, our mainstream sensor is durable and provides reliable readings you can count on. Our mainstream comes with 2 year warranty and the package includes 1 each of the 2 size airway adapters (a larger adapter for tubes greater than 4mm and a smaller adapter for tubes less than or equal to 4mm).

Fast

Measurements are taken at the patient’s airway, so response time is fast – less than 60ms

Easy

Simply snap the sensor onto the airway adapter. There are no clips or latches to break

Accurate

Clear, precious CO2 measurement. No regular calibration is required

Reliable

Rugged design and construction minimized the downtime. No moving parts to replace

Lightweight

At just 25grams. Ideal for every patient

Warranty

2 year warranty
Learn MoreRequest Purchase Information

EtCO2 Sensor - Sidestream

EtCO2 Monitoring Module

EtCO2 monitoring is one of the easiest ways to alert for failing health conditions, such as hyper or hypothermia but requires highly accurate and durable sensor. Our LoFlo sidestream sensor is manufactured by Philips Respironics, using sophisticated infrared absorption spectroscopy to measure EtCO2 and respiration rate. The sensor delivers a clear, precise capnogram for respiratory rates up to 150 breaths per minute. And with a sampling rate of 50ml/min, it is ideal for smaller patients. Our LoFlo sidestream comes with 2 year warranty and the package includes 1 each of the 2 size airway adapters (a larger adapter for tubes greater than 4mm and a smaller adapter for tubes less than or equal to 4mm).

Application Environment

Ideal for ICU, CCU, ER, OR and EMS

Dependable

Delivers clear, precise measurement of EtCO2

Reliable

Rugged design and construction minimizes downtime

Innovative

Sampling cell and filter are attached to the disposable sampling kits, preventing fluids from contaminating the sensor

Easy

Plug and Play functionality. Intuitive and easy to use. No regular calibration required

Warranty

2 year warranty

EtCO2 Monitoring Module

EtCO2 monitoring is one of the easiest ways to alert for failing health conditions, such as hyper or hypothermia but requires highly accurate and durable sensor. Our LoFlo sidestream sensor is manufactured by Philips Respironics, using sophisticated infrared absorption spectroscopy to measure EtCO2 and respiration rate. The sensor delivers a clear, precise capnogram for respiratory rates up to 150 breaths per minute. And with a sampling rate of 50ml/min, it is ideal for smaller patients. Our LoFlo sidestream comes with 2 year warranty and the package includes 1 each of the 2 size airway adapters (a larger adapter for tubes greater than 4mm and a smaller adapter for tubes less than or equal to 4mm).

Application Environment

Ideal for ICU, CCU, ER, OR and EMS

Dependable

Delivers clear, precise measurement of EtCO2

Reliable

Rugged design and construction minimizes downtime

Innovative

Sampling cell and filter are attached to the disposable sampling kits, preventing fluids from contaminating the sensor

Easy

Plug and Play functionality. Intuitive and easy to use. No regular calibration required

Warranty

2 year warranty
Learn MoreRequest Purchase Information
EtCO2 Sensor - B-RSCO2

Bionet EtCO2 Sensor - Mainstream

EtCO2 Monitoring Module

The Bionet Mainstream EtCO₂ Sensor provides continuous measurement of end-tidal CO₂, inspired CO₂, and respiration rate directly at the patient’s airway. Its fast response and compact, lightweight design make it suitable for monitoring veterinary patients during anesthesia, surgery, recovery, and critical care.

The sensor uses dual-wavelength, non-dispersive infrared technology with no moving parts. A capnogram is displayed in less than four seconds, allowing clinicians to quickly assess ventilation and confirm airway status. The heated probe helps reduce condensation inside the airway adapter for more consistent monitoring.

The Bionet Mainstream EtCO₂ Sensor is compatible with Bionet Brio XVet Series and BM Elite Series patient monitors.

Fast

Capnogram displayed in less than 4 seconds, with a response time of less than 500 ms

Direct

Measures EtCO2, inspired CO2, and respiration rate directly at the patient’s airway

Accurate

Dual-wavelength infrared technology provides precise, continuous CO₂ measurement, with anesthetic agent compensation

Condensation Control

Heated probe helps reduce condensation inside the airway adapter for consistent monitoring

Lightweight

Compact, lightweight sensor design minimizes added weight at the patient’s airway

Low Maintenance

No routine gas calibration required. Backed by a 2-year warranty
Image of Bionet EtCO2 Sensor MainStream

EtCO2 Monitoring Module

The Bionet Mainstream EtCO₂ Sensor provides continuous measurement of end-tidal CO₂, inspired CO₂, and respiration rate directly at the patient’s airway. Its fast response and compact, lightweight design make it suitable for monitoring veterinary patients during anesthesia, surgery, recovery, and critical care.

The sensor uses dual-wavelength, non-dispersive infrared technology with no moving parts. A capnogram is displayed in less than four seconds, allowing clinicians to quickly assess ventilation and confirm airway status. The heated probe helps reduce condensation inside the airway adapter for more consistent monitoring.

The Bionet Mainstream EtCO₂ Sensor is compatible with Bionet Brio XVet Series and BM Elite Series patient monitors.

Fast

Capnogram displayed in less than 4 seconds, with a response time of less than 500 ms

Direct

Measures EtCO2, inspired CO2, and respiration rate directly at the patient’s airway

Accurate

Dual-wavelength infrared technology provides precise, continuous CO₂ measurement, with anesthetic agent compensation

Condensation Control

Heated probe helps reduce condensation inside the airway adapter for consistent monitoring

Lightweight

Compact, lightweight sensor design minimizes added weight at the patient’s airway

Low Maintenance

No routine gas calibration required. Backed by a 2-year warranty
Learn MoreRequest Purchase Information

Bionet EtCO2 Sensor - Sidestream

EtCO2 Monitoring Module

The Bionet Sidestream CO₂ Sensor continuously measures end-tidal CO₂, inspired CO₂ and respiration rate using a low sample flow of 50 mL/min. With the CO₂ sensor positioned away from the patient’s airway, only the lightweight sampling connection attaches to the breathing circuit.

Designed for use with the Brio XVet Series, the Bionet Sidestream CO₂ Sensor supports respiratory monitoring during anesthesia, recovery, emergency care and other procedures requiring continuous assessment of ventilation.

The Bionet Sidestream EtCO₂ Sensor is compatible with Bionet Brio XVet Series.

Fast Response

Displays the capnogram in less than four seconds for rapid assessment of patient ventilation

Low Sample Flow

Uses a low 50 mL/min sampling rate to minimize gas removal from the breathing circuit

Broad Patient Compatibility

Sampling options for adult to infant patients accommodate a wide range of veterinary patient sizes

Reliable CO₂ Measurement

Dual-wavelength NDIR technology continuously measures EtCO₂, inspired CO₂ and respiration rate

Lightweight Airway Connection

Keeps the CO₂ sensor away from the patient’s airway, with only the lightweight sampling connection attached to the breathing circuit

Anesthesia Compensation

Supports operator-selectable anesthetic-agent compensation for reliable monitoring during anesthesia

EtCO2 Monitoring Module

The Bionet Sidestream CO₂ Sensor continuously measures end-tidal CO₂, inspired CO₂ and respiration rate using a low sample flow of 50 mL/min. With the CO₂ sensor positioned away from the patient’s airway, only the lightweight sampling connection attaches to the breathing circuit.

Designed for use with the Brio XVet Series, the Bionet Sidestream CO₂ Sensor supports respiratory monitoring during anesthesia, recovery, emergency care and other procedures requiring continuous assessment of ventilation.

The Bionet Sidestream EtCO₂ Sensor is compatible with Bionet Brio XVet Series.

Fast Response

Displays the capnogram in less than four seconds for rapid assessment of patient ventilation

Low Sample Flow

Uses a low 50 mL/min sampling rate to minimize gas removal from the breathing circuit

Broad Patient Compatibility

Sampling options for adult to infant patients accommodate a wide range of veterinary patient sizes

Reliable CO₂ Measurement

Dual-wavelength NDIR technology continuously measures EtCO₂, inspired CO₂ and respiration rate

Lightweight Airway Connection

Keeps the CO₂ sensor away from the patient’s airway, with only the lightweight sampling connection attached to the breathing circuit

Anesthesia Compensation

Supports operator-selectable anesthetic-agent compensation for reliable monitoring during anesthesia
Learn MoreRequest Purchase Information
Image of Bionet EtCO2 Sensor SideStream

GA3VET

EtCO2/Anesthetic Gas Analyzer

Bionet introduces the portable, versatile, and affordable GA3VET EtCO2/anesthetic gas analyzer. At just 2.46 lbs, the GA3VET gives you portable cordless control with sidestream EtCO2 and anesthetic gas monitoring. All with easy wireless compatibility and FREE BT-Link Pro and BT-Link mobile app for real-time monitoring and data recording.

Parameters

EtCO2, FiCO2, RR, Anesthetic Agent Concentration, and MAC

Safety

Prevent over and under dosing patients with anesthetic gases

Touchscreen

7.0″ Color TFT LCD Touchscreen

Monitoring

Connect unit to BT-Link computer software over Wi-Fi

Lightweight

Weighs only 2.46 lbs

Warranty

2 year warranty
Bionet GA3VET - EtCO2/Anesthetic Gas Analyzer

EtCO2/Anesthetic Gas Analyzer

Bionet introduces the portable, versatile, and affordable GA3VET EtCO2/anesthetic gas analyzer. At just 2.46 lbs, the GA3VET gives you portable cordless control with sidestream EtCO2 and anesthetic gas monitoring. All with easy wireless compatibility and FREE BT-Link Pro and BT-Link mobile app for real-time monitoring and data recording.

Parameters

EtCO2, FiCO2, RR, Anesthetic Agent Concentration, and MAC

Safety

Prevent over and under dosing patients with anesthetic gases

Touchscreen

7.0″ Color TFT LCD Touchscreen

Monitoring

Connect unit to BT-Link computer software over Wi-Fi

Lightweight

Weighs only 2.46 lbs

Warranty

2 year warranty
Learn MoreRequest Purchase Information

Request Purchase Information

Interested in learning more about Bionet’s products?

1-877-924-6638