LAB24
Ambulatory Blood Pressure Monitoring
Get accurate and timely blood pressure readings from your patients with the LAB24
Bionet’s LAB24 is an advanced, motion-tolerant ambulatory blood pressure monitor supporting the care and diagnosis of hyper and hypotensive patients. The LAB24 provides 24 hours of blood pressure data within a 48 hours period, allowing breaks for daily activity and rest.
Get accurate and timely blood pressure readings from your patients with the LAB24
Bionet’s LAB24 is an advanced, motion-tolerant ambulatory blood pressure monitor supporting the care and diagnosis of hyper and hypotensive patients. The LAB24 provides 24 hours of blood pressure data within a 48 hours period, allowing breaks for daily activity and rest.
Product Highlights
Motion tolerant algorithm for 24 hrs up to 48 hrs monitoring
Clinically validated (AAMI, ESH, BIHS, AAMI-SP10, ISO 81060-2)
Patented cuffs with inner pocket
Easy wearing & reassuring of BP accuracy
Intuitive, user-friendly Windows based software
Easy to use & one button design
Product Highlights
Motion tolerant algorithm for 24 hrs up to 48 hrs monitoring
Clinically validated (AAMI, ESH, BIHS, AAMI-SP10, ISO 81060-2)
Patented cuffs with inner pocket
Easy wearing & reassuring of BP accuracy
Intuitive, user-friendly Windows based software
Easy to use & one button design
Comfort, Accuracy, Dependability. Experience the LAB24 Ambulatory Blood Pressure monitoring system from Bionet
When blood pressures need to be retried or confirmed due to:
- “White coat” hypertension
- Masked hypertension
- Titrating medication
- Active child induced artifact
- Identifying pre-hyper/hypotension, High normal BP
Identifying NON-Dippers
- 24hr hypertension exposed
- Potential LVH (Left Ventricle Hypertrophy)
- Congestive heart failure
- Potential MI
- Target organ damage
- Stroke & Renal failure
Easy traceable patient data & capacity
- Clinically approved by meeting or exceeding the latest BHS, ESH, AAMI:SP10 standards
- Motion Tolerant algorithm applied
- Patented inner pocket, unique, self-fitting, comfort cuff. Durable for all ABPM applications.
- BMS Mini software for smart programing, analysis tools, and reports
Situations when BP accuracy matters the most
- “White Coat” hypertension: Patient shows hypertension at the doctor’s office but not at other settings, such as home.
- Masked hypertension: Patient shows normal BP at doctor’s office but exhibits hypertension at home or during daily life.
- Titrating medication for antihypertensive medication
- Self BP reading with accuracy is the key for titrating hypertensive medication.
- Other hypertensive symptom needing ABPM
- Resistant hypertension
- Childhood hypertension
- Nocturnal hypertension
- Episodic hypertension and / or anxiety disorders
- Hypotensive symptoms
- Changes in diet and daily routine designed to reduce hypertension
Non-dippers with 24 hr hypertension exposed with high potential LVH (left ventricular hypertrophy)
- Non-dippers are a certain group of patients, particularly those with potential target organ damage or LVH, whose nocturnal systolic and diastolic blood pressure do not respectively average clinically expected lower readings.
- One of the major factors of LVH is continuous exposure to 24 hr hypertension, even during the night.
- LVH gradually changes the structure of the heart by thickening the left ventricle chamber wall and complications can include:
- Arrhythmia
- Stroke
- Cardiac Arrest
- As a prevention, regular basis BP monitoring is critical with accurate 24 hr monitoring, as well as moderate physical activities, dietary control and, above all, quitting smoking.
Why LAB24 ABPM ?
- Motion tolerant algorithm for 24 hrs up to 48 hrs monitoring
The most advanced BP algorithm for day/night monitoring even under circumstances of motion artifact. - Clinically validated by standards of
AAMI, ESH, BIHS, AAMI-SP10, ISO 81060-2 - Patented cuffs with inner pocket for easy wearing & reassuring BP accuracy
Equipped with inner-pocket design, it will hold cuff position for BP monitoring, ensuring accurate, consistent readings. - BMS Mini ABPM software is intuitive, user-friendly Windows based program that includes:
- Interpretive summary report
- Time-slice periods with statistical analysis
- Custom report options with single page with ABP graph
- PDF report format with EMR compatibility with built-in direct email menu
- Easy to use & one button design
- Simple operation with one button design
- 250 memory readings
- 2 AA batteries required
Includes:
Lab24 ABP Monitor, USB Cable, ABP Monitor Belt, ABP Monitor Shoulder Strap, Pouch, ABPM Cuff – Size 2 (26cm-34cm), ABPM Cuff – Size 3 (32cm-44cm), NIBP Hose Female to Female Extension, Multilingual Quick Guide & Instruction for use (USB Drive), BMS-Mini Software (USB Drive)
| wdt_ID | Method of Measurement | Oscillometric with step deflation |
|---|---|---|
| 73 | Blood Pressure Range | Systolic: 40-260mmHg Diastolic: 25-200 mmHg |
| 74 | Heart Rate Range | 40-200 bpm |
| 75 | Maximum Inflate Pressure | 280 mmHg |
| 77 | Accuracy | Heart Rate accurate within +/-2% or +/-3 bpm, whichever is greater. Blood Pressure results meet or exceed ANSI/AAMI/ISO 81060-2:2013 standards for noninvasive accuracy: ±5 mmHg mean error & 8 mmHg standard deviation. |
| 78 | Validations | Clinically validated to ANSI/AAMI/ISO 81060-2:2013, BHS (A/A), and ESH International Protocol. |
| 79 | Operating Conditions | 10°C (50°F) to 50°C (122°F) 20-95% RH non-condensing |
| 80 | Shipping/Storage Conditions | -20°C (-4°F) to 70°C (158°F) 15-95% RH non-condensing |
| 82 | Classification | Continuous operation Power: Two (2) AA batteries, alkaline |
| 83 | Data Memory | Flash memory stores up to 250 readings |
| 84 | Calibration Check Recommendation | Minimally, once every two years |
| 85 | Safety Systems | Maximum inflation pressure limited to 300 mmHg; Auto safety release valve for power failure; Maximum measurement time limited to less than 140 seconds |
| 86 | Sampling Periods | 24 independently programmable time periods (Time interval options: none, 5, 10, 15, 20, 30, 45, 60, 90, and 120 minutes) |
| wdt_ID | Parameter | Standard | EU Norm |
|---|---|---|---|
| 73 | Safety | AAMI/ANSI ES60601-1:2005/(R) 2012 +A1:2012 | EN 60601-1 :2006/A1:2013/ IEC 60601-1: 2005/A1:2012 |
| 74 | Blood Pressure | IEC 80601-2-30 :2009 + A1:2013 | N/A |
| 75 | Usability | IEC 60601-1-6 :2013 Ed. 3.1 IEC 62366:2015 Ed. 1.0 |
EN 60601-1-6 :2010 EN 62366:2008 |
| 77 | EMC/EMI/ESD | IEC60601-1-2:2014 | EN 60601-1-2:2015 |
| 78 | Home Use | IEC 60601-1-11:2015 Ed. 2.0 | EN IEC 60601-1-11:2010 |
| 79 | Biocompatibility | ISO 10993-1:2009/(R)2013 ISO 10993-5:2009 ISO 10993-10:2010 |
EN ISO 10993-1:2009/AC:2010 EN ISO 10993-5:2009 N/A |
| 80 | Software | IEC 62304:2015 | EN IEC 62304:2006/AC:2008 |
| 82 | Symbols | ISO 15223-1:2016 | EN ISO 15223-1:2016 |
| 83 | Sphygmomanometers | ANSI/AAMI/ISO 81060-2:2013 | EN ISO 81060-1:2012 |
| 84 | Quality | ISO 13485:2016 | EN ISO 13485:2016 |
| 85 | Risk Management | ISO 14971:2007 (Ed. 2) | EN ISO 14971:2012 |
| 86 | Size | Approximately 100 x 70 x 30 mm | |
| 87 | Weight | Approximately 233 g, including batteries | |
| 88 | Storage Conditions | -20° C to +70° C, 15%-95% RH non-condensing | |
| 89 | Data | USB 3.0 (USB-C) |
* Specifications can be changed without prior notification.
- Overview
-
Comfort, Accuracy, Dependability. Experience the LAB24 Ambulatory Blood Pressure monitoring system from Bionet
When blood pressures need to be retried or confirmed due to:
- “White coat” hypertension
- Masked hypertension
- Titrating medication
- Active child induced artifact
- Identifying pre-hyper/hypotension, High normal BP
Identifying NON-Dippers
- 24hr hypertension exposed
- Potential LVH (Left Ventricle Hypertrophy)
- Congestive heart failure
- Potential MI
- Target organ damage
- Stroke & Renal failure
Easy traceable patient data & capacity
- Clinically approved by meeting or exceeding the latest BHS, ESH, AAMI:SP10 standards
- Motion Tolerant algorithm applied
- Patented inner pocket, unique, self-fitting, comfort cuff. Durable for all ABPM applications.
- BMS Mini software for smart programing, analysis tools, and reports
Situations when BP accuracy matters the most
- “White Coat” hypertension: Patient shows hypertension at the doctor’s office but not at other settings, such as home.
- Masked hypertension: Patient shows normal BP at doctor’s office but exhibits hypertension at home or during daily life.
- Titrating medication for antihypertensive medication
- Self BP reading with accuracy is the key for titrating hypertensive medication.
- Other hypertensive symptom needing ABPM
- Resistant hypertension
- Childhood hypertension
- Nocturnal hypertension
- Episodic hypertension and / or anxiety disorders
- Hypotensive symptoms
- Changes in diet and daily routine designed to reduce hypertension
Non-dippers with 24 hr hypertension exposed with high potential LVH (left ventricular hypertrophy)
- Non-dippers are a certain group of patients, particularly those with potential target organ damage or LVH, whose nocturnal systolic and diastolic blood pressure do not respectively average clinically expected lower readings.
- One of the major factors of LVH is continuous exposure to 24 hr hypertension, even during the night.
- LVH gradually changes the structure of the heart by thickening the left ventricle chamber wall and complications can include:
- Arrhythmia
- Stroke
- Cardiac Arrest
- As a prevention, regular basis BP monitoring is critical with accurate 24 hr monitoring, as well as moderate physical activities, dietary control and, above all, quitting smoking.
Why LAB24 ABPM ?
- Motion tolerant algorithm for 24 hrs up to 48 hrs monitoring
The most advanced BP algorithm for day/night monitoring even under circumstances of motion artifact. - Clinically validated by standards of
AAMI, ESH, BIHS, AAMI-SP10, ISO 81060-2 - Patented cuffs with inner pocket for easy wearing & reassuring BP accuracy
Equipped with inner-pocket design, it will hold cuff position for BP monitoring, ensuring accurate, consistent readings. - BMS Mini ABPM software is intuitive, user-friendly Windows based program that includes:
- Interpretive summary report
- Time-slice periods with statistical analysis
- Custom report options with single page with ABP graph
- PDF report format with EMR compatibility with built-in direct email menu
- Easy to use & one button design
- Simple operation with one button design
- 250 memory readings
- 2 AA batteries required
Includes:
Lab24 ABP Monitor, USB Cable, ABP Monitor Belt, ABP Monitor Shoulder Strap, Pouch, ABPM Cuff – Size 2 (26cm-34cm), ABPM Cuff – Size 3 (32cm-44cm), NIBP Hose Female to Female Extension, Multilingual Quick Guide & Instruction for use (USB Drive), BMS-Mini Software (USB Drive) - Specifications
-
wdt_ID Method of Measurement Oscillometric with step deflation 73 Blood Pressure Range Systolic: 40-260mmHg
Diastolic: 25-200 mmHg74 Heart Rate Range 40-200 bpm 75 Maximum Inflate Pressure 280 mmHg 77 Accuracy Heart Rate accurate within +/-2% or +/-3 bpm, whichever is greater.
Blood Pressure results meet or exceed ANSI/AAMI/ISO 81060-2:2013 standards for noninvasive accuracy: ±5 mmHg mean error & 8 mmHg standard deviation.78 Validations Clinically validated to ANSI/AAMI/ISO 81060-2:2013, BHS (A/A), and ESH
International Protocol.79 Operating Conditions 10°C (50°F) to 50°C (122°F)
20-95% RH non-condensing80 Shipping/Storage Conditions -20°C (-4°F) to 70°C (158°F)
15-95% RH non-condensing82 Classification Continuous operation
Power: Two (2) AA batteries, alkaline83 Data Memory Flash memory stores up to 250 readings 84 Calibration Check Recommendation Minimally, once every two years 85 Safety Systems Maximum inflation pressure limited to 300 mmHg; Auto safety release valve for power failure; Maximum measurement time limited to less than 140 seconds 86 Sampling Periods 24 independently programmable time periods (Time interval options: none, 5, 10, 15, 20, 30, 45, 60, 90, and 120 minutes) wdt_ID Parameter Standard EU Norm 73 Safety AAMI/ANSI ES60601-1:2005/(R) 2012 +A1:2012 EN 60601-1 :2006/A1:2013/ IEC
60601-1: 2005/A1:201274 Blood Pressure IEC 80601-2-30 :2009 + A1:2013 N/A 75 Usability IEC 60601-1-6 :2013 Ed. 3.1
IEC 62366:2015 Ed. 1.0EN 60601-1-6 :2010
EN 62366:200877 EMC/EMI/ESD IEC60601-1-2:2014 EN 60601-1-2:2015 78 Home Use IEC 60601-1-11:2015 Ed. 2.0 EN IEC 60601-1-11:2010 79 Biocompatibility ISO 10993-1:2009/(R)2013
ISO 10993-5:2009
ISO 10993-10:2010EN ISO 10993-1:2009/AC:2010
EN ISO 10993-5:2009
N/A80 Software IEC 62304:2015 EN IEC 62304:2006/AC:2008 82 Symbols ISO 15223-1:2016 EN ISO 15223-1:2016 83 Sphygmomanometers ANSI/AAMI/ISO 81060-2:2013 EN ISO 81060-1:2012 84 Quality ISO 13485:2016 EN ISO 13485:2016 85 Risk Management ISO 14971:2007 (Ed. 2) EN ISO 14971:2012 86 Size Approximately 100 x 70 x 30 mm 87 Weight Approximately 233 g, including batteries 88 Storage Conditions -20° C to +70° C, 15%-95% RH non-condensing 89 Data USB 3.0 (USB-C) * Specifications can be changed without prior notification.
- Downloads